articleTop 10% cited
MRI simulation-based evaluation of image-processing and classification methods
IEEE Transactions on Medical Imaging · 1999 · Vol. 18(11) · pp. 1085–1097
Roberta Kwan✉(Montreal Neurological Institute and Hospital)Alan C. Evans(Montreal Neurological Institute and Hospital)G. Bruce Pike(McGill University)
Abstract
With the increased interest in computer-aided image analysis methods, there is a greater need for objective methods of algorithm evaluation. Validation of in vivo MRI studies is complicated by a lack of reference data and the difficulty of constructing anatomically realistic physical phantoms. We present here an extensible MRI simulator that efficiently generates realistic three-dimensional (3-D) brain images using a hybrid Bloch equation and tissue template simulation that accounts for image contrast, partial volume, and noise. This allows image analysis methods to be evaluated with controlled degradations of image data.
Advanced MRI Techniques and ApplicationsNMR spectroscopy and applicationsMedical Imaging Techniques and ApplicationsComputer scienceImage processingArtificial intelligencePartial volumeImage (mathematics)Computer visionReal-time MRINoise (video)Pattern recognition (psychology)Magnetic resonance imaging
MeSH terms
BrainHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingPhantoms, Imaging
Citations
706
FWCI
4.09
field-weighted impact
References
34
Percentile
94%
vs. same field & year
Citations per year
Cited by
Generalized Overlap Measures for Evaluation and Validation in Medical Image Analysis
IEEE Transactions on Medical Imaging · 2006 · 797 citations
Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis
IEEE Transactions on Medical Imaging · 2002 · 764 citations
Advances in functional and structural MR image analysis and implementation as FSL
NeuroImage · 2004 · 13,980 citations
References
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Physical Review · 1954 · 6,369 citations
The intrinsic signal‐to‐noise ratio in NMR imaging
Magnetic Resonance in Medicine · 1986 · 753 citations
Application of Fourier Transform Spectroscopy to Magnetic Resonance
Review of Scientific Instruments · 1966 · 1,641 citations
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Review of Scientific Instruments · 1958 · 5,910 citations
Design and construction of a realistic digital brain phantom
IEEE Transactions on Medical Imaging · 1998 · 1,823 citations
Morphometric analysis of white matter lesions in MR images: method and validation
IEEE Transactions on Medical Imaging · 1994 · 1,264 citations
Automatic 3‐D model‐based neuroanatomical segmentation
Human Brain Mapping · 1995 · 986 citations
Measurement of signal intensities in the presence of noise in MR images
Medical Physics · 1985 · 1,013 citations
Related articles
MRI simulation-based evaluation of image-processing and classification methods
IEEE Transactions on Medical Imaging · 1999 · 706 citations
Citation Network
How this paper connects to the literature. Drag to explore, click any node to open that paper.
