Scinovex
articleTop 1% cited

Learning a variational network for reconstruction of accelerated MRI data

Magnetic Resonance in Medicine · 2017 · Vol. 79(6) · pp. 3055–3071
Kerstin HammernikTeresa KlatzerErich KoblerMichael P. RechtDaniel K. SodicksonThomas PockFlorian Knöll

Abstract

Variational network reconstructions preserve the natural appearance of MR images as well as pathologies that were not included in the training data set. Due to its high computational performance, that is, reconstruction time of 193 ms on a single graphics card, and the omission of parameter tuning once the network is trained, this new approach to image reconstruction can easily be integrated into clinical workflow. Magn Reson Med 79:3055-3071, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Advanced MRI Techniques and ApplicationsMedical Imaging Techniques and ApplicationsCardiac Imaging and DiagnosticsCompressed sensingComputer scienceAccelerationGradient descentArtificial intelligenceAlgorithmIterative reconstructionVariational methodDeep learningArtificial neural network

MeSH terms

Machine LearningAdolescentAdultAgedAlgorithmsComputer SimulationFemaleHumansImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedMagnetic Resonance ImagingMaleMiddle AgedRetrospective StudiesReproducibility of Results

Funding

  • National Institutes of Health
Citations
1,659
FWCI
96.94
field-weighted impact
References
53
Percentile
100%
vs. same field & year
Citations per year
Cited by
MoDL: Model-Based Deep Learning Architecture for Inverse Problems
IEEE Transactions on Medical Imaging · 2018 · 955 citations
Deep learning in medical imaging and radiation therapy
Medical Physics · 2018 · 725 citations
Learned Primal-Dual Reconstruction
IEEE Transactions on Medical Imaging · 2018 · 692 citations
References
Unsupervised texture segmentation using Gabor filters
Pattern Recognition · 1991 · 2,127 citations
Sparse MRI: The application of compressed sensing for rapid MR imaging
Magnetic Resonance in Medicine · 2007 · 6,856 citations
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Magnetic Resonance in Medicine · 2002 · 5,259 citations
Fields of Experts
International Journal of Computer Vision · 2009 · 860 citations
Image quality assessment: from error visibility to structural similarity
IEEE Transactions on Image Processing · 2004 · 54,590 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.