Scinovex
article

Venous Return at Various Right Atrial Pressures and the Normal Venous Return Curve

American Journal of Physiology-Legacy Content · 1957 · Vol. 189(3) · pp. 609–615
Arthur C. GuytonA. W. LindseyBerry AbernathyTravis Q. Richardson

Abstract

The normal venous return curve has been determined in 12 open-chest dogs with intact circulatory reflexes and in 14 open-chest areflex dogs. These curves show that venous return reaches a maximum value when the right atrial pressure falls to –2 to –4 mm Hg and remains at this maximum value down to infinitely low negative pressures. As the right atrial pressure rises to positive values venous return falls and reaches zero when the right atrial pressure has risen to equal the mean circulatory pressure. A venous return curve for the normal, intact dog has been tentatively formulated on the basis of these studies and previous studies in which individual points on the venous return curves of intact dogs have been measured.

Cardiovascular Function and Risk FactorsHeart Rate Variability and Autonomic ControlCardiac Arrhythmias and TreatmentsVenous return curveMean circulatory filling pressureCentral venous pressureCirculatory systemCardiologyMedicineVenous pressureInternal medicineAnesthesiaBlood pressure

MeSH terms

HeartHumansVeinsAtrial Pressure
Citations
539
FWCI
0.00
field-weighted impact
References
0
Percentile
9%
vs. same field & year
Citations per year
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.