Scinovex
articleTop 1% cited

Exact and approximate rebinning algorithms for 3-D PET data

IEEE Transactions on Medical Imaging · 1997 · Vol. 16(2) · pp. 145–158
Michel DefrisePaul E. KinahanD.W. TownsendChristian MichelM. SibomanaD.F. Newport

Abstract

This paper presents two new rebinning algorithms for the reconstruction of three-dimensional (3-D) positron emission tomography (PET) data. A rebinning algorithm is one that first sorts the 3-D data into an ordinary two-dimensional (2-D) data set containing one sinogram for each transaxial slice to be reconstructed; the 3-D image is then recovered by applying to each slice a 2-D reconstruction method such as filtered-backprojection. This approach allows a significant speedup of 3-D reconstruction, which is particularly useful for applications involving dynamic acquisitions or whole-body imaging. The first new algorithm is obtained by discretizing an exact analytical inversion formula. The second algorithm, called the Fourier rebinning algorithm (FORE), is approximate but allows an efficient implementation based on taking 2-D Fourier transforms of the data. This second algorithm was implemented and applied to data acquired with the new generation of PET systems and also to simulated data for a scanner with an 18 degrees axial aperture. The reconstructed images were compared to those obtained with the 3-D reprojection algorithm (3DRP) which is the standard "exact" 3-D filtered-backprojection method. Results demonstrate that FORE provides a reliable alternative to 3DRP, while at the same time achieving an order of magnitude reduction in processing time.

Medical Imaging Techniques and ApplicationsAdvanced MRI Techniques and ApplicationsRadiation Detection and Scintillator TechnologiesIterative reconstructionAlgorithmComputer scienceReconstruction algorithmSpeedupFourier transformImage processingData setArtificial intelligenceComputer vision

MeSH terms

AlgorithmsBrainFourier AnalysisHumansImage Processing, Computer-AssistedTomography, Emission-ComputedPhantoms, Imaging
Citations
749
FWCI
17.03
field-weighted impact
References
44
Percentile
100%
vs. same field & year
Citations per year
Cited by
New, faster, image-based scatter correction for 3D PET
IEEE Transactions on Nuclear Science · 2000 · 515 citations
Time of flight in PET revisited
IEEE Transactions on Nuclear Science · 2003 · 333 citations
References
The Mathematics of Computerized Tomography
Medical Physics · 2002 · 2,575 citations
Accelerated image reconstruction using ordered subsets of projection data
IEEE Transactions on Medical Imaging · 1994 · 3,675 citations
Analytic 3D image reconstruction using all detected events
IEEE Transactions on Nuclear Science · 1989 · 761 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.