Scinovex
articleTop 1% cited

Adaptive fuzzy segmentation of magnetic resonance images

IEEE Transactions on Medical Imaging · 1999 · Vol. 18(9) · pp. 737–752
Dzung L. PhamJerry L. Prince

Abstract

An algorithm is presented for the fuzzy segmentation of two-dimensional (2-D) and three-dimensional (3-D) multispectral magnetic resonance (MR) images that have been corrupted by intensity inhomogeneities, also known as shading artifacts. The algorithm is an extension of the 2-D adaptive fuzzy C-means algorithm (2-D AFCM) presented in previous work by the authors. This algorithm models the intensity inhomogeneities as a gain field that causes image intensities to smoothly and slowly vary through the image space. It iteratively adapts to the intensity inhomogeneities and is completely automated. In this paper, we fully generalize 2-D AFCM to three-dimensional (3-D) multispectral images. Because of the potential size of 3-D image data, we also describe a new faster multigrid-based algorithm for its implementation. We show, using simulated MR data, that 3-D AFCM yields lower error rates than both the standard fuzzy C-means (FCM) algorithm and two other competing methods, when segmenting corrupted images. Its efficacy is further demonstrated using real 3-D scalar and multispectral MR brain images.

Medical Image Segmentation TechniquesImage and Signal Denoising MethodsImage Retrieval and Classification TechniquesMultispectral imageImage segmentationArtificial intelligenceFuzzy logicComputer scienceSegmentationComputer visionAlgorithmPattern recognition (psychology)Mathematics

MeSH terms

AlgorithmsBrainComputer SimulationHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingFuzzy Logic
Citations
796
FWCI
17.22
field-weighted impact
References
42
Percentile
100%
vs. same field & year
Citations per year
Cited by
HAMMER: hierarchical attribute matching mechanism for elastic registration
IEEE Transactions on Medical Imaging · 2002 · 1,076 citations
A Review of Methods for Correction of Intensity Inhomogeneity in MRI
IEEE Transactions on Medical Imaging · 2007 · 834 citations
Unified segmentation
NeuroImage · 2005 · 7,438 citations
A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data
IEEE Transactions on Medical Imaging · 2002 · 1,785 citations
References
B-spline signal processing. I. Theory
IEEE Transactions on Signal Processing · 1993 · 923 citations
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
IEEE Transactions on Medical Imaging · 1998 · 4,793 citations
Statistical approach to segmentation of single-channel cerebral MR images
IEEE Transactions on Medical Imaging · 1997 · 693 citations
Adaptive segmentation of MRI data
IEEE Transactions on Medical Imaging · 1996 · 1,275 citations
Citation Network