article Open AccessTop 1% cited
Clinical Utility of Doppler Echocardiography and Tissue Doppler Imaging in the Estimation of Left Ventricular Filling Pressures
Circulation · 2000 · Vol. 102(15) · pp. 1788–1794
Steve R. Ommen✉(Mayo Clinic)R A Nishimura(Mayo Clinic)C. P. Appleton(Mayo Clinic)Fletcher A. Miller(Mayo Clinic)Jae K. Oh(Mayo Clinic)Margaret M. Redfield(Mayo Clinic)A. Jamil Tajik(Mayo Clinic)
Abstract
The combination of tissue Doppler imaging of the mitral annulus and mitral inflow velocity curves provides better estimates of LV filling pressures than other methods (pulmonary vein, preload reduction). However, accurate prediction of filling pressures for an individual patient requires a stepwise approach incorporating all available data.
Cardiovascular Function and Risk FactorsCardiac Valve Diseases and TreatmentsCardiac Imaging and DiagnosticsMedicinePreloadCardiologyInternal medicineDoppler effectDiastoleDoppler echocardiographyDoppler imagingEjection fractionPulmonary wedge pressure
MeSH terms
AgedDiastoleFemaleHeartHumansMaleMiddle AgedEchocardiography, DopplerVentricular FunctionVentricular Function, Left
Citations
2,782
FWCI
16.02
field-weighted impact
References
37
Percentile
99%
vs. same field & year
Citations per year
Cited by
Epidemiology of Heart Failure
Circulation Research · 2013 · 1,722 citations
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
European Heart Journal · 2016 · 11,387 citations
Left atrial volume as a morphophysiologic expression of left ventricular diastolic dysfunction and relation to cardiovascular risk burden
The American Journal of Cardiology · 2002 · 1,152 citations
How to diagnose diastolic heart failure: a consensus statement on the diagnosis of heart failure with normal left ventricular ejection fraction by the Heart Failure and Echocardiography Associations of the European Society of Cardiology
European Heart Journal · 2007 · 2,670 citations
Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine
Intensive Care Medicine · 2014 · 1,738 citations
References
Assessment of Mitral Annulus Velocity by Doppler Tissue Imaging in the Evaluation of Left Ventricular Diastolic Function
Journal of the American College of Cardiology · 1997 · 1,562 citations
Doppler Tissue Imaging: A Noninvasive Technique for Evaluation of Left Ventricular Relaxation and Estimation of Filling Pressures
Journal of the American College of Cardiology · 1997 · 3,013 citations
Heart Disease: A Textbook of Cardiovascular Medicine.
Annals of Internal Medicine · 1984 · 4,135 citations
Citation Network
How this paper connects to the literature. Drag to explore, click any node to open that paper.
