Scinovex
articleTop 1% cited

Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization

Physics in Medicine and Biology · 2008 · Vol. 53(17) · pp. 4777–4807
Emil Y. SidkyXiaochuan Pan

Abstract

An iterative algorithm, based on recent work in compressive sensing, is developed for volume image reconstruction from a circular cone-beam scan. The algorithm minimizes the total variation (TV) of the image subject to the constraint that the estimated projection data is within a specified tolerance of the available data and that the values of the volume image are non-negative. The constraints are enforced by the use of projection onto convex sets (POCS) and the TV objective is minimized by steepest descent with an adaptive step-size. The algorithm is referred to as adaptive-steepest-descent-POCS (ASD-POCS). It appears to be robust against cone-beam artifacts, and may be particularly useful when the angular range is limited or when the angular sampling rate is low. The ASD-POCS algorithm is tested with the Defrise disk and jaw computerized phantoms. Some comparisons are performed with the POCS and expectation-maximization (EM) algorithms. Although the algorithm is presented in the context of circular cone-beam image reconstruction, it can also be applied to scanning geometries involving other x-ray source trajectories.

Medical Imaging Techniques and ApplicationsAdvanced X-ray and CT ImagingAdvanced MRI Techniques and ApplicationsProjection (relational algebra)Iterative reconstructionGradient descentCone beam computed tomographyContext (archaeology)MathematicsMinificationConstraint (computer-aided design)Compressed sensingRange (aeronautics)

MeSH terms

AlgorithmsComputer SimulationHumansImage Processing, Computer-AssistedModels, TheoreticalRadiographic Image Interpretation, Computer-AssistedSoftwareX-RaysModels, StatisticalTomography Scanners, X-Ray ComputedArtifactsPhantoms, ImagingImaging, Three-DimensionalCone-Beam Computed Tomography
Citations
1,946
FWCI
31.41
field-weighted impact
References
55
Percentile
100%
vs. same field & year
Citations per year
Cited by
The PyHST2 hybrid distributed code for high speed tomographic reconstruction with iterative reconstruction and a priori knowledge capabilities
Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · 2014 · 485 citations
Deep Convolutional Neural Network for Inverse Problems in Imaging
IEEE Transactions on Image Processing · 2017 · 2,465 citations
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
IEEE Transactions on Medical Imaging · 2017 · 1,776 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.